Find help with height safety and roof anchor inspections for Melbourne properties.

Height safety system design

How a height safety designer works through the Victorian hierarchy of fall controls to lay out access, anchors, lines and guardrails on a Melbourne roof.

Height safety design is the work of deciding, for one roof, how each person who goes up there will get on, move around and do their task without being exposed to a fall. The designer lists the tasks, then works through the Victorian hierarchy of controls from the top: remove the need to go up, then passive protection such as guardrails, then restraint, then fall arrest, and only then ladders or procedures. The result is a drawn layout of access points, edge protection, anchors, static lines and walkways that an installer can price and build.

Illustrative photo for Height safety system design

Melbourne Height Safety does not draw or certify designs. The enquiry goes to an independent provider who carries the design and its sign-off.

Why design before buying anchors?

Many roofs end up with anchors scattered wherever the last contractor needed one. The result is gaps where nobody can reach the gutter safely, anchors too close to the edge to use for restraint, and no clear route from the hatch to the plant. A design looks at the roof as a whole. It often finds that a short length of guardrail near the access point, plus a few well placed anchors, covers more tasks than a dozen anchors bought one at a time.

Design also comes up when the roof changes. Solar arrays, new condensers, extra exhaust fans and replacement roof sheets can block existing anchors or create new trip and fall hazards. If a new installation is planned, design the access around it before the panels go down.

The hierarchy of controls a designer works through

The Occupational Health and Safety Regulations 2017 require an employer to eliminate the risk of a fall where reasonably practicable and, if not, to reduce it using the highest practicable level below. WorkSafe Victoria’s falls compliance code sets the five levels out in a table. The roof examples below are typical applications on existing buildings, not quotes from the code.

Level Control Roof examples
1 Eliminate the risk, work on the ground or a solid construction Relocate plant to ground level, use extended poles for gutter cleaning from the ground
2 Passive fall prevention device Guardrailing along roof edges and around skylight openings, roof safety mesh
3 Work positioning system Travel restraint lines that stop a worker reaching the edge, industrial rope access
4 Fall arrest system Harness, lanyard and anchors or static lines that catch a fall
5 Ladder or administrative controls Fixed or portable ladder used correctly, written work procedures, permits to access the roof

The code adds that, when choosing between two otherwise equal options from the same level, the one needing less operator skill is preferred. Its own example is a perimeter guardrail, which needs no ongoing skill from the person it protects, chosen ahead of an elevating work platform. Where only administrative controls are used, the regulations require the employer to record the control and the task before the work starts.

What the designer will need from you

  • Roof plans or architectural drawings, and structural drawings if they exist.
  • A list of every task on the roof, who does it and how often: gutter cleaning, HVAC servicing, solar maintenance, window or facade cleaning, antenna work.
  • Photos of the access point and the roof surface, especially skylights and older sheeting.
  • Any planned roof works, such as solar or plant replacement.
  • Existing height safety reports, so the design can reuse sound equipment.

What a good design includes

  1. A roof plan showing every access point, guardrail, anchor, static line, walkway and fragile area.
  2. For each task, the control chosen and why higher controls were not reasonably practicable.
  3. Fall clearance checks for any fall arrest element.
  4. The structure each anchor will fix to, with a note that it has been checked by a competent person as suitable.
  5. Sign content for the access point.
  6. A rescue approach. Where work positioning, fall arrest, ladders or administrative controls are relied on, the OHS Regulations require the employer to set up emergency procedures before the task starts, so a worker who falls can be rescued and given first aid straight away. A worker held by a harness has to be reached and brought down, and the design should say how.
  7. The standards the components are to meet, such as AS 5532 for single-point anchors and AS/NZS 1891.2 for horizontal lines.

Fragile roofs and skylights

The regulations name tasks on a fragile surface among the fall hazards an employer must identify. The compliance code gives cement sheeting roofs, rusty metal roofs, fibreglass sheeting and skylights as examples. A designer should mark these on the plan and either cover or guard them, or route walkways and lines so nobody needs to step near them. Industrial roofs like those across Dandenong South can include translucent sheets that look solid from a distance. Ageing sheeting on any older building deserves the same caution.

Heritage, planning and visibility

Guardrails and walkways can be seen from the street. On heritage buildings, council may need to approve visible rooftop works. In Richmond and the rest of Yarra, the council says a property in a heritage overlay needs a planning permit for most works. The designer can often place edge protection behind parapets or use low profile options, but check with council before the installation is ordered.

What a careful designer will not do

They will not jump straight to harness anchors without explaining why guardrails or elimination were not reasonably practicable. They will not specify anchors into structure nobody has checked, will not ignore fall clearance on a low roof, and will not design around equipment they have not seen in place. If the design relies on administrative controls for any task, they will say so plainly so the employer can record it.

Cost and next steps

Design fees depend on roof size, the number of tasks and whether drawings already exist. The Melbourne height safety cost guide covers how design is usually priced against installation. After installation, the system moves into the routine of anchor inspections and recertification, and a full compliance report can follow once everything is in place.

To start, describe the roof and the tasks on it in a design enquiry. Mention any upcoming solar or plant work so the layout can allow for it.

Send a job enquiry

Frequently asked questions

Do I need a design for a small roof?

Not always. If one or two tasks are done near a hatch, a provider may recommend a small number of anchors without a full design. A design pays off when there are several tasks, several roof levels, plant near edges or fragile sheeting.

Who should prepare a height safety design?

Someone competent in fall protection who can assess the roof structure or get it assessed. Ask whether the designer works for an installer, and whether you can take the design to other installers for competing quotes.

Can the design be done from drawings alone?

Drawings are a good start, but a site visit usually finds things the drawings miss, such as added plant, skylights, damaged sheeting and how the hatch actually opens. Most designs need at least one look at the roof.

Will a design cover solar panels I plan to install?

It should, if you tell the designer about them. Planning the panels and the access layout together avoids anchors being covered or panels blocking the safe route to gutters and plant.