Roof anchor point inspection and recertification
What a roof anchor inspection checks, how often WorkSafe guidance expects one, and what the inspector needs from a Melbourne building owner or manager.
A roof anchor inspection is a check by a competent person that each fixed anchor on a roof is still correctly installed, undamaged and fit to hold a person who falls, followed by a tag and a written record. WorkSafe Victoria’s compliance code for falls in construction says a permanently fixed anchorage in regular use is inspected by a competent person “at no less than six-month intervals” during a project, an anchorage not in regular use is inspected before anyone uses it, and every anchorage is visually checked before each use. Outside a construction project, ask the inspector to state the interval they are applying to your system and where it comes from: the manufacturer’s instructions and the maintenance part of AS/NZS 1891.4 are the usual references.

Melbourne Height Safety is a referral service; an independent inspector you engage quotes, attends and signs the report.
Why do roof anchors need regular inspection?
An anchor sits on a roof for years in sun, rain and wind, and it is only loaded when someone falls. Fixings can loosen as roof sheets expand and contract, sealants around the base perish, corrosion starts where dissimilar metals touch, and anchors get knocked by trades moving plant across the roof. An anchor can also be fine in itself but fixed into a purlin or slab that has since been cut, notched or overloaded.
The other reason is paperwork. Window cleaners, roof plumbers, HVAC technicians and solar installers may ask to see a current inspection record before they go up, because their employer has its own duty to control the risk of a fall.
Signs an anchor needs attention before the next scheduled check
- The inspection tag is missing, unreadable or past its date.
- Rust staining, cracked sealant or a leak in the ceiling directly below an anchor.
- The anchor eye is bent, the post leans or the base plate has lifted.
- Someone has fallen and been held by the anchor. The code says a system that has arrested a fall is checked by a competent person and not used again until verified as serviceable.
- New solar panels, condensers or ductwork have been built around or over the anchor.
- Nobody can find the roof plan that shows where the anchors are and what each one is rated for.
Inspection outcomes compared
| Outcome | What it means | What normally follows |
|---|---|---|
| Pass | Anchor is installed as designed, undamaged and suitable for its marked use | New tag with the inspection date, entry in the report |
| Pass with notes | Anchor is usable but something needs fixing, such as worn signage or a resealed base | Minor works listed with a timeframe |
| Fail | Damaged, corroded, wrongly installed or fixed to unsuitable structure | Tagged out of service so nobody uses it, replacement or repair quoted, re-inspected before use |
| Cannot verify | The fixing cannot be seen or there is no installation record | Further investigation, which may mean opening the ceiling or a proof test by the method the manufacturer allows |
The code is clear that an impaired anchorage is tagged so it is not used, and that a repaired one stays out of use until a competent person confirms it is safe.
What the inspector will check
- The roof access point: ladder, hatch or door, and whether reaching the first anchor is itself safe.
- Each anchor’s fixing to the structure, whether through-bolted, chemically fixed or clamped, against the manufacturer’s method.
- Visible damage, corrosion, deformation and the condition of the sealant and flashing around each penetration.
- That the anchor type matches its job. A travel restraint anchor and a fall arrest anchor are not interchangeable. AS 5532 sets the manufacturing requirements for single-point anchor devices, so the inspector looks for its marking.
- Labels, the roof layout plan and the sign at the access point that tells users which anchors to use and how.
- Any static line, rail or ladder fitted alongside. Those have their own checks, covered on the static line systems page and the ladders and walkways page.
What to have ready
- Keys or codes for the roof hatch or plant room, and the name of whoever controls roof access.
- The last inspection report and the original installation certificate if you have them.
- The as-installed roof plan or any photos of the anchor layout.
- A list of who uses the roof and why: gutter cleaning, plant servicing, solar, window cleaning or rope access.
- Any changes since the last inspection, such as reroofing or new equipment.
If the building has never had an inspection, say so in the enquiry, because the first visit takes longer.
The Victorian rules behind the inspection
The Occupational Health and Safety Regulations 2017 set a hierarchy for controlling the risk of a fall of more than two metres. An employer works down from eliminating the risk, to passive protection such as guardrails, to a work positioning system such as travel restraint, to a fall arrest system, and only then to ladders or administrative controls. Anchors sit in the work positioning and fall arrest levels, so they only do their job if they are maintained.
Building owners carry a separate duty. Under the Occupational Health and Safety Act 2004, whoever has management or control of a workplace, including an owner, must make the workplace and the ways in and out of it safe so far as is reasonably practicable. For strata buildings, an owners corporation has a statutory duty under the Owners Corporations Act 2006 to keep its common property, and the fittings on it, repaired and maintained. Read the WorkSafe compliance code on preventing falls in construction for the inspection guidance quoted above.
What a careful inspector will not do
A careful inspector will not tag an anchor they could not properly examine, will not pass an anchor on a roof structure that looks compromised just because the anchor itself is fine, and will not leave a failed anchor in service while a quote is prepared. They will not load test an anchor by a method the manufacturer does not allow. If they also sell replacements, expect them to explain why a failed item cannot be repaired before recommending new hardware.
Melbourne buildings and anchor inspections
The work changes with the building. City towers such as those covered on the Melbourne CBD area page can carry a large number of anchors, rope access points and rooftop plant zones, so the report becomes a register. Industrial roofs in places like Dandenong South have long metal roof runs where anchors and static lines share the load of gutter and skylight work. Smaller walk-up blocks may have only two or three anchors near a hatch, yet the same rules apply.
Cost and next steps
Inspection fees depend on the number of anchors, how hard the roof is to reach and the state of the records. The height safety cost guide explains what moves the price. If the inspection turns up a layout problem, a height safety design may be the better next step than replacing anchors one by one.
To arrange a check, send the building address and anchor details through the quote form. Include the number of anchors if you know it, the last inspection date and how the roof is reached. The provider who takes up the enquiry confirms scope and price with you directly.
Frequently asked questions
- What is the difference between inspection and recertification?
People use the words loosely. An inspection is the physical check of each anchor. Recertification usually means the inspector has found the anchor fit for use, updated its tag and issued a written record dated from that visit.
- Can my maintenance person check the anchors?
Anyone using an anchor should look it over before clipping on. The periodic inspection is a different task and should be done by a competent person who knows the system and the manufacturer's requirements, and who will put their name to the result.
- What happens if an anchor fails inspection?
It should be tagged so nobody uses it, and you should be told straight away rather than waiting for the written report. The provider then quotes a repair or replacement, and the anchor stays out of service until a competent person confirms it is safe again.
- Do I need the original installation certificate?
It helps a great deal. Without it, the inspector may not be able to confirm how an anchor was fixed and may need to investigate further before passing it. If you cannot find it, ask the original installer or the builder before the inspection.
- How long does an anchor inspection take?
That varies with the number of anchors, the size of the roof and how easy it is to get up there. A small roof with a few anchors and good records is quick; a tower with many roof levels and no plan takes much longer. Ask the provider for an estimate when they quote.